Loading...
HomeMy WebLinkAboutOrd 1994-486 ORDINANCE #94-48 AN ORDINANCE OF THE MAYOR AND COMMON COUNCIL OF THE TOWN OF FOUNTAIN HILLS, ARIZONA, AMENDING THE CHAPTER 7 BUILDINGS AND BUILDING REGULATIONS, SECTION 7-1-1 ADOPTION BY REFERENCE; VIOLATIONS OF THE CODE OF THE TOWN OF FOUNTAIN HILLS,4RIZONA BY ADDING SUBSECTION 7. "THE 1991 EDITION OF THE UNIFORM PLUMBING CODE AND ALL SUPPLEMENTS". WHEREAS On June 28, 1990, the Mayor and Common Council passed Ordinance #90-8 which adopted The Code of the Town of Fountain Hills; and WHEREAS Chapter 7 of The Code of the Town of Fountain Hills specifies the building construction codes are to be followed in the Town of Fountain Hills; and WHEREAS Building codes are updated to reflect improved construction materials and techniques, and to prohibit unsafe construction procedures and materials; and ® WHEREAS The 1991 Uniform Plumbing Code and all supplements to this code provide for improved plumbing procedures and materials and prohibits practices and materials that are no longer safe or satisfactory; and NOW THEREFORE, BE IT ORDAINED BY THE MAYOR AND COMMON COUNCIL OF THE TOWN OF FOUNTAIN HILLS, ARIZONA AS FOLLOWS: Section 1. Chapter 7, Section 7-1-1, of The Code of the Town of Fountain Hills is hereby amended to add subsection 7. as follows: 7. The Uniform Plumbing Code, 1991 Edition and all supplements; with the following exceptions: A. Replacing Table 10-2 with Attachment "A" B. Add to Section 409 (B) the following language: "For the purposes of this subsection, the word 'approved' shall be defined as , as design submitted to the Town of Fountain Hills, reviewed and approved by the Fountain Hills Sanitary District and the Town of Fountain Hills Building Official. The Town of Fountain Hills or the Fountain Hills Sanitary District may require the design to be engineered by an Arizona registered engineer." kQ+:rr.: Couv\L l)m4,- �r,A' Gair�c lwon�a�W'y4i5l�of� Tu-bl F. • Tim« �GSS2c1, tlY�O.h. �JJ y, El �J PASSED AND ADOPTED BY the Mayor and Common Council of the Town of Fountain Hills, Arizona, this day of -b t-(xw.b-4-r , 1994. FOR THE TOWN OF FOUNTAIN HILLS: 2 John tillo, Mayor REVIEWED BY: L APaul4Nordin., own Manager ATTESTED TO: cj _AA '1l &A � Cassie B. Hansen, Town Clerk APPROVED AS TO FORM: illiam E. Farrell, Town Attorney • UNIFORM C PLUMBING CODE"" IONAI FOUNDED 1926 '_ 6 MW N -i 6 CODE CHANGES ADOPTED 1993 UPC Changes Adopted 19 Table 10-2 (item isl) ® Fixture Unit Table for Determining Water Pipe and Meter Sizes PRESSURE RANGE - 30 to 45 per- Maur Balding Sud supply street and Wshnum Allowable Length in Feet (meters) service (heaths) branches (inefw) 40 60 80 109 150 290 250 300 400 500 600 700 800 800 1000 (12) (18) (24) (30) (46) (81) (76) (91) (122) (152) (183) (213) (244) (74) (305) 3/4 12— 6 5 4 3 2 1 1 1 0 0 0 0 0 0 0 34 34 16 16 14 12 9 6 5 5 4 4 3 2 2 2 1 3k 1 29 25 23 21 17 15 13 12 10 8 6 6 6 6 6 1 1 36 31 27 25 20 17 15 13 12 10 8 6 6 6 6 314 1-1/4 36 33 31 28 24 23 21 19 17 16 13 12 12 11 11 1 1.1/4 54 47 42 38 32 28 25 23 19 17 14 12 12 11 11 1.12 1-1/4 78 6B 57 48 38 32 29 25 21 18 15 12 12 11 11 1 1.12 95 84 79 65 56 48 43 38 32 28 26 22 21 20 20 1-12 1.12 150 124 105 91 70 57 49 45 36 31 26 23 21 20 20 2 1.12 151 129 129 110 80 64 53 46 38 32 27 23 21 20 20 1 2 95 85 85 85 85 85 82 80 66 61 57 52 49 46 43 1.12 2 220 205 190 176 155 138 127 120 104 85 70 61 57 54 51 2 2 370 327 282 265 217 185 164 147 124 96 70 61 57 54 51 2 2.112 445 418 390 370 330 300 280 265 240 220 198 175 158 143 133 PRESSURE RANGE-46 to 60 per" Mehr Su0Ing anti supply street and Maldmum Allowable Length In Fest (nets,$) service Drerndes (Inchn) (Inches) 40 60 80 100 150 200 259 300 400 500 800 700 800 900 1000 (12) (18) (24) (30) (46) (4h) (76) (91) (122) (152) (183) 913) (244) ("4) (305) 314 12" 7 7 6 5 4 3 2 2 1 1 1 0 0 0 0 ® 314 314 20 20 19 17 14 11 8 8 6 5 4 4 3 3 3 34 1 39 39 36 33 28 23 21 19 17 14 12 10 9 8 8 1 1 39 39 39 36 30 25 23 20 18 15 12 10 9 8 6 314 1-1/4 39 39 39 39 39 39 34 32 27 25 22 19 19 17 16 1 1.1/4 78 78 76 67 52 44 39 36 30 27 24 20 19 17 16 1-12 1-1/4 78 78 78 78 66 52 44 39 33 29 24 20 19 17 16 1 1-12 65 65 95 95 85 85 60 67 55 49 41 37 34 32 30 1-12 1-12 151 151 151 151 128 105 90 78 62 52 42 38 35 32 30 2 1.12 151 151 151 151 150 117 98 84 67 55 42 38 35 32 30 1 2 85 85 85 85 85 85 95 85 95 95 85 85 85 93 80 1-12 2 370 370 340 318 271 240 220 198 170 150 135 123 110 102 94 2 2 370 370 370 370 368 318 280 250 205 165 142 123 110 102 94 2 2-12 654 640 610 580 535 500 470 440 400 365 335 315 285 267 250 PRESSURE RANGE - Over 60 per" Meter Bulkling and Supply street service nd brennenas Msldrnum Allowable Length In Fen (reefers) (Incline) (techs) 40 80 80 100 150 200 2S0 300 400 500 600 700 800 9110 1000 (12) (18) (24) (30) (46) (61) (76) (=I) (122) (152) (183) 913) (244) (274) (305) 314 12- 7 7 7 6 5 4 3 3 2 1 1 1 1 1 0 314 314 20 20 20 20 17 13 11 10 B 7 6 6 5 4 4 314 1 39 39 39 39 35 30 27 24 21 17 14 13 12 12 11 1 1 39 39 39 39 38 32 29 26 22 18 14 13 12 12 11 314 1-1/4 39 39 39 39 39 39 39 39 34 28 26 25 23 22 21 1 1-1/4 78 78 78 78 74 62 53 47 39 31 26 25 23 22 21 1.12 1.114 78 78 78 78 78 74 65 54 43 34 26 25 23 22 21 1 1-12 95 85 85 95 85 95 85 95 81 64 51 48 46 43 40 1-12 1-12 151 151 151 151 151 151 130 113 68 73 51 51 46 43 40 2 1.12 151 151 151 151 151 151 142 122 98 82 64 51 46 43 40 1 2 85 85 85 85 85 85 85 95 85 85 85 85 95 85 85 1-12 2 370 370 370 370 360 335 305 282 214 212 187 172 153 141 129 2 2 370 370 370 370 370 370 370 340 288 245 204 172 153 141 129 2 2.12 654 654 654 654 654 650 610 570 510 460 430 404 380 356 329 "Building supply, three-quarter (314) inch nominal size minimum. "'Available static pressure after head loss.